Receive data contains errors Change Equalization settings to better
match cable transmission properties
Termination settings are incorrect
(should measure 150Ohm if On,
40KOhm if Off)
Test Mode B does not echo sent charac-
ter
Set Equalization to setting 1 (minimum)
U character is not issued in Test Mode C Set Equalization to setting 1 (minimum)
Change Baud rate at DTE to 19,200
Table 4 - Trouble Shooting Guide (Continued)